Cell Sorting
Cell Sorting - Instruments
-
BD Influx 10L
Overview: 10 Laser, 24 parameter jet in air cell sorter
Lasers: 355nm, 405nm, 445nm, 488nm, 514nm, 532nm, 561nm, 594nm, 635nm, 786nm
22 colour + 2 scatter parametersSample acquisition of 30,000 events/second
Capabilities:
- 1-8 Way Sorting
- Class II Biological Safety Cabinet
- Cooled sample delivery and collection
- Collection: tubes 5mL - 50mL, plates 6-384-well, slides
- Index Sorting
- Nozzles: 70um, 85um, 100um, 140um, 200um
- Highly configurable -
BD Influx 7L
Overview: 7 Laser, 24 parameter jet in air cell sorter
Lasers: 355nm, 405nm, 488nm, 514nm, 561nm, 640nm, 786nm
22 colour + 2 scatter parametersSample acquisition of 30,000 events/second
Capabilities:
- 1-6 Way Sorting
- Class II Biological Safety Cabinet
- Cooled sample delivery and collection
- Collection: tubes 5mL - 50mL, plates 6-384-well, slides
- Index Sorting
- Nozzles: 70um, 85um, 100um, 140um, 200um
- Highly configurable -
BD Influx 3L - PC3
Overview: 3 Laser, 17 parameter jet in air cell sorter housed within a PC3 facility
Lasers: 405nm, 488nm, 628nm
15 colour + 2 scatter parametersSample acquisition of 30,000 events/second
Capabilities:
- 1-6 Way Sorting
- Class II Biological Safety Cabinet
- Collection: 5mL - 50mL, plates 6-384-well, slides
- Index Sorting
- Nozzles: 100um, 140um
- Highly-configurable -
BD FACSAria IIu
Overview: 3 Laser, 13 parameter quartz cuvette flow cell, cell sorter
Lasers: 405nm, 488nm, 628nm
11 colour + 2 scatter parametersSample acquisition of 20,000 events/second
Capabilities:
- 1-4 Way Sorting
- Class I Biological Safety Cabinet
- Cooled sample collection
- Collection: tubes 1.5mL-15mL, plates 96-384-well
- Nozzles: 70um, 85um, 100um, 130um -
BD FACSMelody
Overview: 3 Laser, 10 parameter quartz cuvette flow cell, cell sorter
Laser: 405nm, 488nm, 561nm
8 colour + 2 scatterSample acquisition of 8,500 events/second
Capabilities:
- 2 Way Sorting
- Class II Biological Safety Cabinet
- Collection: tubes 5mL, plates 96-384-well
- Nozzle: 100um -
Sony MA900
The MA900 from Sony meets the needs of most sorting applications, supporting 12 fluorescence parameters and 4-way sorting.
Powerful, modern technologies built into the MA900 system include a patented micro fluidic chip-based design, comprehensive fluidic controls, and advanced automation that dramatically simplifies operation to make sorting less subjective and improve reliability.
Up to 14 parameters from 4 lasers
The MA900 offers choice and flexibility, enabling the detection of up to 14 parameters. Choose from 4 excitation lasers—488 nm, 405 nm, 561 nm, and 638 nm—on two beam spots. Free-form PMTs enable detection of fluorescence signals from each beam spot, allowing detection of up to 12 fluorescence parameters and two scatter parameters.